36000GPD Commercial Reverse Osmosis Water Treatment System
Product Details:
Place of Origin: | China |
Brand Name: | Fenigal/OEM |
Certification: | CE/NSF etc. |
Model Number: | TM/BM-12K~36k |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | Standard Export Wood Crate/Carton or Naked wrapped by film |
Delivery Time: | 15~30 days |
Payment Terms: | T/T, Western Union, Paypal etc. |
Supply Ability: | 50 set per month |
Detail Information |
|||
Technology: | Commercial Water Reverse Osmosis | Design: | Skid Mount |
---|---|---|---|
Permeate Flow/TPD: | 45~136 | Recovery Rate: | 65~75% |
Feed TDS/ppm: | <2,000 | Water Temp.: | 5~35˚C |
PH: | 4~9 | TSS/mg/L: | <5 |
Silt Density Index: | <3 | Free Chlorine Mg/L: | 0 |
Dissolved Iron Mg/L: | <0.1 | Warranty: | 1 Year |
Material: | SS304/SS316L,carbon Steel | Capacity: | 0.5-100m3/h |
Voltage: | 380V,415V,220V,can Be Customized | Application: | Water Purification,Filtration,pharmceutical,drinking Water,food |
Size: | Depends,1750*550*1650mm | Type: | Reverse Osmosis System |
Function: | Water Purifying, Desalination | Desalination Rate: | 99%,99.7% |
Control: | Electronic,Manual/PLC | Ro Membrane: | Vontron, Hydranautics Or DOW,4040 |
Pump: | CNP / Grundfos,CNP | ||
High Light: | 36000GPD commercial reverse osmosis water treatment system,OEM commercial reverse osmosis water treatment system,SS304 ro commercial water purifier |
Product Description
36000GPD Commercial Reverse Osmosis Water Treatment System
TM/BM Commercial reverse osmosis water treatment system 12,000GPD~36,000GPD
TM/BM Series Reverse Osmosis Systems are designed for overall superior performance, high recovery rates, minimal
energy consumption and offer great savings with low maintenance and low operation costs.
The TM/BM Series Reverse Osmosis Systems range in capacities from 12,000 to 36,000 gallons per day. To achieve higher recovery rates, each base model includes a concentrate recycle loop.
These systems can be upgraded with features such as a variable frequency drive, digital instrumentation, a chemical feed system, blending valve and a permeate divert valve.
Benefits
Fully Equipped and Customizable Skid Mounted Components Easily Accessible Pre–Plumbed, Wired and Assembled |
Individually Tested and Preserved Low Operation and Maintenance Costs Easy Maintenance and Servicing |
20% Less Energy than Standard Membranes 1–Year Limited Warranty |
Features
Models: TM/BM 4240, TM/BM 6240, TM/BM 8240 Micro-computer Controller LCD Backlit Display Pre–Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm Hour Meter Feed Flush
|
Models: TM/BM 10240, TM/BM 12240 Micro-computer Controller LCD Backlit Display Pre–Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm Hour Meter Dual TDS Monitoring Feed Flush Digital Flow Meters x 3 Rejection Percentage Recovery Percentage
|
Permeate and Concentrate Flow Meters* Concentrate Recycle Flow Meter* Stainless Steel Concentrate Globe Valve Pre–Filter 0 – 100 psi Panel Mounted Glycerin Filled Gauges Pump Discharge and Concentrate 0 – 300 psi Panel Mounted Glycerin Filled Gauges |
Bag Filter Housing with Stainless Steel Stand 5 – Micron Filter Bag Ultra Low Energy Membrane Elements FRP Membrane Housings – 300 psi Vertical Multi–Stage Stainless Steel Booster Pump |
Feed Solenoid Valve Feed Low Pressure Switch Clean–In–Place (CIP) Ports Permeate Sample Ports White Powder Coated Aluminum Frame Wooden Shipping Crate |
Options and Upgrades
Dual TDS Board
Micro-computer Controller
Nanofiltration Membrane Elements
ORP Meter*
pH Meter*
S – 200 ORP Monitoring*
S – 200 pH Monitoring*
Chemical Pump Outlet
Blending Valve
High Pressure Tank Switch
Pump Pressure Relief Valve**
Caster Wheels
Permeate Divert
Variable Frequency Drive
Array Specifications
Vessel Array | Vessel Size | Vessel Quantity | Membrane Size | Membrane Quantity | |
TM/BM 4240 | 2:2 | 4080 | 4 | 4040 | 8 |
TM/BM 6240 | 2:2:2 | 4080 | 6 | 4040 | 12 |
TM/BM 8240 | 3:3:2 | 4080 | 8 | 4040 | 16 |
TM/BM 10240 | 3:3:2:2 | 4080 | 10 | 4040 | 20 |
TM/BM 12240 | 3:3:2:2:2 | 4080 | 12 | 4040 | 24 |
Product Specifications
Models | TM/BM 4240 | TM/BM 6240 | TM/BM 8240 | TM/BM 10240 | TM/BM 12240 |
Design | |||||
Configuration | Single Pass | Single Pass | Single Pass | Single Pass | Single Pass |
Feedwater Source† | TDS <2,000 ppm | TDS <2,000 ppm | TDS <2,000 ppm | TDS <2,000 ppm | TDS <2,000 ppm |
Standard Recovery Rate % | 50 – 75 | 50 – 75 | 50 – 75 | 50 – 75 | 60 – 75 |
Rejection and Flow Rates | |||||
Nominal Salt Rejection % | 98.5 | 98.5 | 98.5 | 98.5 | 98.5 |
Permeate Flow (gpm / lpm) | 8.30 / 31.42 | 12.50 / 47.32 | 16.70 / 63.22 | 20.80 / 78.74 | 25.00 / 94.63 |
Minimum Feed Flow (gpm / lpm) | 14.30 / 54.00 | 18.50 / 70.00 | 22.70 / 85.93 | 26.80 / 101.45 | 31.00 / 117.35 |
Maximum Feed Flow (gpm / lpm) | 28.00 / 106.00 | 28.00 / 106.00 | 42.00 / 159.00 | 42.00 / 159.00 | 42.00 / 159.00 |
Minimum Concentrate Flow (gpm / lpm) | 6.00 / 22.70 | 6.00 / 22.70 | 6.00 / 22.70 | 6.00 / 22.70 | 6.00 / 22.70 |
Connections | |||||
Feed (in) | 1.5 FNPT | 1.5 FNPT | 1.5 FNPT | 1.5 FNPT | 1.5 FNPT |
Permeate (in) | 1 FNPT | 1 FNPT | 1 FNPT | 1.5 FNPT | 1.5 FNPT |
Concentrate (in) | 1 FNPT | 1 FNPT | 1 FNPT | 1.5 FNPT | 1.5 FNPT |
CIP (in) | 1 FNPT | 1 FNPT | 1 FNPT | 1 FNPT | 1 FNPT |
Membranes | |||||
Membrane(s) Per Vessel | 2 | 2 | 2 | 2 | 2 |
Membrane Quantity | 8 | 12 | 16 | 20 | 24 |
Membrane Size | 4040 | 4040 | 4040 | 4040 | 4040 |
Vessels | |||||
Vessel Array | 2:2 | 2:2:2 | 3:3:2 | 3:3:2:2 | 3:3:2:2:2 |
Vessel Quantity | 4 | 6 | 8 | 10 | 12 |
Pumps | |||||
Pump Type | Multi–Stage | Multi–Stage | Multi–Stage | Multi–Stage | Multi–Stage |
Motor HP | 3 | 3 | 5 | 7.5 | 7.5 |
RPM @ 60 Hz | 3450 | 3450 | 3450 | 3450 | 3450 |
RPM @ 50 Hz | 2900 | 2900 | 2900 | 2900 | 2900 |
System Electrical | |||||
Standard Voltage + Amp Draw | 220V, 60Hz, 3PH, 9A** | 220V, 60Hz, 3PH, 9A** | 220V, 60Hz, 3PH, 14.2A** | 220V, 60Hz, 3PH, 19.5A** | 220V, 60Hz, 3PH, 19.5A** |
Voltage Options + Amp Draw | 220V, 50Hz, 3PH, 10.6A** 460V, 60Hz, 3PH, 5A** |
220V, 50Hz, 3PH, 10.6A** 460V, 60Hz, 3PH, 5A** |
220V, 50Hz, 3PH, 16.1A** 460V, 60Hz, 3PH, 7A** |
220V, 50Hz, 3PH, 22.9A** 460V, 60Hz, 3PH, 9.7A** |
220V, 50Hz, 3PH, 22.9A** 460V, 60Hz, 3PH, 9.7A** |
Systems Dimensions | |||||
Approximate Dimensions* L x W x H (in / cm) | 31 x 100 x 64 / 78.74 x 254 x 162.56 |
31 x 100 x 64 / 78.74 x 254 x 162.56 |
31 x 100 x 64 / 78.74 x 254 x 162.56 |
31 x 100 x 64 / 78.74 x 254 x 162.56 |
31 x 100 x 64 / 78.74 x 254 x 162.56 |
Approximate Weight (lbs / kg) | 1060 / 480.81 | 1150 / 476.27 | 1260 / 571.53 | 1350 / 612.35 | 1450 / 657.71 |
Test Parameters: 550 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 80 psi / 5.5 bar Operating Pressure,
77ªF / 25ªC, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.
* Does not include operating space requirements.
** Varies with motor manufacturer.
Operating Limits
Maximum Feed Temperature (°F / °C) | 85 / 29 | Maximum Turbidity (NTU) | 1 |
Minimum Feed Temperature (°F / °C) | 40 / 5 | Maximum Free Chlorine (ppm) | 0 |
Maximum Ambient Temperature (°F / °C) | 120 / 49 | Maximum TDS (ppm) | 2000 |
Minimum Ambient Temperature (°F / °C) | 40 / 4 | Maximum Hardness (gpg) | 0 |
Maximum Feed Pressure (psi / bar) | 85 / 6 | Maximum pH (Continuous) | 11 |
Minimum Feed Pressure (psi / bar) | 45 / 3 | Minimum pH (Continuous) | 2 |
Maximum Operating Pressure (psi / bar) | 200 / 14 | Maximum pH (Cleaning 30 Minutes) | 13 |
Maximum Feed Silt Density Index (SDI) | <3 | Minimum pH (Cleaning 30 Minutes) | 1 |
- Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer
- projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.
- System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.
- Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.