Place of Origin: China
Brand Name: Fenigal/OEM
Certification: CE/NSF etc.
Model Number: TX/BX -32k~190K

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard Export Wood Crate/Carton or Naked wrapped by film
Delivery Time: 15~30 days
Payment Terms: T/T, Western Union, Paypal etc.
Supply Ability: 50 set per month
Get Best Price Contact Now

Detail Information

Technology: Commercial Water Reverse Osmosis Design: Skid Mount
Permeate Flow/TPD: 120-720 Recovery Rate: 65~75%
Feed TDS/ppm: <2,000 Water Temp.: 5~35˚C
PH: 4~9 TSS/mg/L: <5
Silt Density Index: <3 Free Chlorine Mg/L: 0
Dissolved Iron Mg/L: <0.1 Warranty: 1 Year
Material: SS304/SS316L,carbon Steel Voltage: 380V,415V,220V,can Be Customized
Application: Water Purification,Filtration,pharmceutical,drinking Water,food Size: Depends,1750*550*1650mm
Type: Reverse Osmosis System Function: Water Purifying, Desalination
Desalination Rate: 99%,99.7% Control: Electronic,Manual/PLC
Ro Membrane: Vontron, Hydranautics Or DOW,4040 Pump: CNP / Grundfos,CNP
High Light:

190000GPD Reverse Osmosis Water Treatment System

,

SS316L Reverse Osmosis Water Treatment System

,

190000GPD ro system water treatment plant

Product Description

OEM 190000GPD Reverse Osmosis Water Treatment System

TX/BX industrial water reverse osmosis system treatment purification 32,000~190,000GPD

TX/BX – Series Reverse Osmosis Systems are designed as a cost–effective solution to the growing demand of tap and

well water for applications in food and beverage, pharmaceutical, healthcare, microelectronics, power, chemicals and agriculture.

With models ranging from 22 to 132 gallons per minute (32,000 to 190,000 gallons per day), the smart, clean utilitarian industrial design of the TX/BX – Series allows for convenient installation, user–friendly operation and ease of maintenance. These skid–mounted, package systems are pre–plumbed and pre–wired on a powder–coated steel frame complete with a pre–programmed computer controller, TDS probes and panel–mounted pressure gauges and flow instrumentation, allowing for straight forward system monitoring and control. The TX/BX – Series Systems utilize energy–efficient ultra low energy membranes with 10% greater membrane surface area than standard 8–inch

reverse osmosis elements, thus producing more pure water.

 

Standard Features

  • Pre–Programmed Computer Controller*
  • with or without VFD (Variable Frequency Drive)**
  • 8 – inch Low Energy Membrane Elements
  • 8 – inch Fiberglass Membrane Housings with Stainless Steel Side Ports (300 psi)
  • 5 – Micron Sediment Cartridge Filters Multi–Cartridge 304L Stainless Steel
  • Cartridge Housing
  • Permeate and Concentrate Rotameters*
  • Permeate and Concentrate Digital
  • Paddlewheel Sensors**
  • Pre– and Post– Filter Pressure Gauges
  • Pump Pressure and Concentrate
  • Pressure Gauges
  • Feed and Permeate TDS
  • Composite Feed Solenoid Valve*
  • Motorized Feed Valve**
  • Stainless Steel Globe Throttling Valves*
  • Low and High Pressure Shut–Off Switches
  • Efficient Vertical Stainless Steel
  • Multi–Stage Pump
  • Powder Coated Carbon Steel Frame
  • PVC Piping
  • Clean–In–Place (CIP) Ports with Valves
  • Permeate Sample Valves
  • Chemical Feed Ports
  • Chemical Feed Power Outlet
  • 380~415VAC 3PH 50HZ

 

Options and Upgrades

  • Programmable Logic Controller (PLC) with Touch Screen
  • Permeate and Concentrate Digital Paddlewheel Sensors
  • PVC Feed Motorized Ball Valve***
  • Concentrate Recycle Loop with Flow Meter
  • PVC Permeate Divert Motorized Ball Valve
  • Permeate Flush
  • pH Sensor
  • ORP Sensor
  • Chemical Feed System
  • Clean–In–Place Skid–Mounted System
  • Voltage Options: 220VAC 3PH 60Hz, 460VAC 3PH 60Hz

* Standard on Models TX/BX – 2280, TX/BX – 3280, TX/BX – 4280, TX/BX – 5280.

** Standard on Models TX/BX – 3480, TX/BX – 4480, TX/BX – 5480, TX/BX – 6480.

*** Option available for Models TX/BX – 2280, TX/BX – 3280, TX/BX – 4280, TX/BX – 5280. Standard on larger models.

 

  Product Specifications  
Models TX/BX – 2280 TX/BX – 3280 TX/BX – 4280 TX/BX – 5280 TX/BX – 3480 TX/BX – 4480 TX/BX – 5480 TX/BX – 6480
Design
Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass
Feedwater Source† TDS TDS TDS TDS TDS TDS TDS TDS
<2,000 ppm <2,000 ppm <2,000 ppm <2,000 ppm <2,000 ppm <2,000 ppm <2,000 ppm <2,000 ppm
Standard Recovery % 61 70 75 75 75 75 75 75
Recovery with Concentrate 80 80 80 N/A N/A N/A N/A N/A
Recycle gpm %
Rejection and Flow Rates †††
Nominal Salt Rejection % 99 99 99 99 99 99 99 99
Permeate Flow Rate 22.00 / 33.00 / 44.00 / 55.00 / 66.00 / 88.00 / 110.00 / 132.00 /
(gpm / lpm) 83 125 167 208 250 333 416 500
Minimum Concentrate 14 / 53 14 / 53 14.6 / 55 18.3 / 69 22 / 83 29 / 111 36.6 / 139 44 / 167
Flow Rate (gpm / lpm)
Connections
Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 3 FNPT 3 FNPT 3 FNPT 3 FNPT
Permeate Connection (in) 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 1/2 FNPT 2 1/2 FNPT 3 FNPT 3 FNPT
Concentrate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT
Clean–in–Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT
Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
Membranes
Membrane(s) Per Vessel 2 2 2 2 4 4 4 4
Membrane Quantity 4 6 8 10 12 16 20 24
Membrane Size 8040 8040 8040 8040 8040 8040 8040 8040
Vessels
Vessel Array 1:01 1:01:01 1:1:1:1 2:1:1:1 2:01 2:01:01 3:01:01 3:02:01
Vessel Quantity 2 3 4 5 3 4 5 6
Pumps
  Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical
Pump Type Multi–Stage Multi–Stage Multi–Stage Multi–Stage Multi–Stage Multi–Stage Multi–Stage Multi–Stage
  Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump
Motor HP / KW 10 / 7.5 10 / 7.5 10 / 7.5 10 / 7.5 15 / 11 15 / 11 20 / 11 20 / 11
System Electrical
Standard Voltage 208V – 230V, 208V – 230V, 208V – 230V, 208V – 230V, 208V – 230V, 208V – 230V, 208V – 230V, 208V – 230V,
+ Amp Draw 60Hz, 3PH, 60Hz, 3PH, 60Hz, 3PH, 60Hz, 3PH, 60Hz, 3PH, 60Hz, 3PH, 60Hz, 3PH, 60Hz, 3PH,
  28A – 27A** 28A – 27A** 28A – 27A** 28A – 27A** 40.5A – 37A** 40.5A – 37A** 49A** 49A**
Systems Dimensions
Approximate Dimensions* L x W x H (in / cm) 112 x 35 x 74 / 112 x 35 x 74 / 112 x 35 x 74 / 112 x 35 x 74 / 194 x 41 x 78 / 194 x 41 x 78 / 194 x 41 x 78 / 194 x 41 x 84 /
284 x 89 x 188 284 x 89 x 188 284 x 89 x 188 284 x 89 x 188 493 x 104 x 198 493 x 104 x 198 493 x 104 x 198 493 x 104 x 213
Approximate Weight 1,285 / 583 1,435 / 651 1,585 / 719 1,735 / 787 2,005 / 910 2,275 / 1,032 2,645 / 1,200 2,910 / 1,320
(lbs / kg)
                     

 

Test Parameters: 550 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 100 psi / 6.9 bar Operating Pressure

77ªF / 25ªC, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

* Does not include operating space requirements.

** Varies with motor manufacturer.

 

Operating Limits

Design Temperature (°F / °C) 77 / 25 Maximum SDI Rating (SDI) < 3
Maximum Feed Temperature (°F / °C) 85 / 29 Maximum Free Chlorine (ppm) 0
Minimum Feed Temperature (°F / °C) 40 / 4 Maximum Hardness (gpg) 0
Maximum Ambient Temperature (°F / °C) 120 / 49 Maximum pH (Continuous) 11
Minimum Ambient Temperature (°F / °C) 40 / 4 Minimum pH (Continuous) 2
Maximum Feed Pressure (psi / bar) 85 / 6 Maximum pH (Cleaning 30 Minutes) 13
Minimum Feed Pressure (psi / bar) 45 / 3 Minimum pH (Cleaning 30 Minutes) 1
Maximum Piping Pressure (psi / bar) 200 / 18.7 Maximum Turbidity (NTU) < 1

 

Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.

System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.