DuPont™ SFP-2880 UF Module – Cost-Effective RO Pretreatment & Water Reuse
Product Details:
| Place of Origin: | China |
| Brand Name: | Dupont |
| Certification: | CE |
| Model Number: | SFP-2880 |
| Document: | UF-IntegraTec-P-Series-PVDF...en.pdf |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 pc |
|---|---|
| Price: | Negotiable |
| Packaging Details: | standard export packing |
| Delivery Time: | 5- 8 work days |
| Payment Terms: | ,T/T |
| Supply Ability: | 60000 Units per Month |
|
Detail Information |
|||
| Module Flux Range Of Component: | 40–90 LMH (24–53 Gfd) At 25°C | Module Flow Rate Of SFP-2880: | 2.0–6.9 M³/hr (8.8–30.4 Gpm) |
|---|---|---|---|
| Module Temperature Limits Of SFP-2880: | 1–40°C (34–104°F) | Module Max Operating TMP Of SFP-2880: | 2.1 Bar (30.5 Psi) |
| Module Chemical Tolerance: | Withstands Up To 2,000 Mg/L NaOCl | Module Optimized Design: | 77m2 |
| Wide Application Range Of SFP-2880: | Suitable For Treating Surface Water, Seawater, Municipal Drinking Water Production | Membrane Type: | Industrial Grade Ultrafiltration Membrane Components |
Product Description
Protect your reverse osmosis system and reduce operational expenses with the DuPont™ SFP-2880. This robust UF module serves as a critical barrier, efficiently removing contaminants that cause RO fouling. By ensuring superior feed water quality, it extends RO membrane lifespan, minimizes chemical cleaning, and lowers the total cost of ownership for your water treatment plant.
- Advanced Filtration Performance: Removes bacteria, viruses, and colloids with high efficiency; achieves filtrate turbidity below 0.1 NTU and SDI under 2.5; ideal protection for reverse osmosis systems
- Engineered Durability: Chemical-resistant PVDF membrane withstands extreme pH conditions; U-PVC housing eliminates need for pressure vessels; operating temperature range supports global deployments
- High-Efficiency Design: Industry-leading membrane area enables high flow rates; outside-in flow handles high solids loading; reduced backwash frequency lowers water consumption
- Operational Reliability: Consistent performance in municipal and industrial settings; minimal maintenance requirements; compatible with automated control systems
| Attribute | Value |
|---|---|
| UF Module Flux Range | 40–90 LMH (24–53 gfd) at 25°C |
| Flow Rate per Module | 2.0–6.9 m³/hr (8.8–30.4 gpm) |
| UF Module Temperature Limits | 1–40°C (34–104°F) |
| UF Module Max Operating TMP | 2.1 bar (30.5 psi) |
| Chemical Tolerance | Withstands up to 2,000 mg/L NaOCl |
| Membrane Area | 77m² |
| Membrane Type | Industrial Grade Ultrafiltration Membrane Components |
| Model | Type | Part # | Membrane Area (m²/ft²) | Volume (Liters/Gallons) | Weight (Kg/lbs) |
|---|---|---|---|---|---|
| SFP-2880 | Pretreatment | 280934 | 77 / 829 | 39 / 10.3 | 61 / 135 (empty), 100 / 220 (water filled) |
| SFD-2880 | NSF/ANSI 61 Drinking water | 324169 | 77 / 829 | 39 / 10.3 | 61 / 135 (empty), 100 / 220 (water filled) |
| Parameter | SI Units | US Units |
|---|---|---|
| Filtrate Flux @ 25ºC | 40-120 l/m²/hr | 24-70 gfd |
| Flow range | 3.1-9.3 m³/hr | 13.6 - 40.9 gpm |
| Temperature | 1-40ºC | 34-104ºF |
| Max. inlet module pressure (@ 20ºC) | 6.25 bar | 93.75 psi |
| Max. operating TMP | 2.1 bar | 30 psi |
| Max operating air scour flow | 12 nm³/hr | 7.1 scfm |
| Max backwash pressure | 2.5 bar | 36 psi |
| Operating pH | 2-11 | |
For application cases, please visit: www.fgwater.com/Industries/