10TPH FRP Tanks Reverse Osmosis Water Plant For Sea Water Desalination
Product Details:
Place of Origin: | China |
Brand Name: | Fenigal |
Certification: | CE |
Model Number: | Brackish Water Reverse Osmosis Water Plant |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 pc |
---|---|
Price: | Negotiable |
Packaging Details: | standard export packing |
Delivery Time: | 5- 8 work days |
Supply Ability: | 60000 Units per Month |
Detail Information |
|||
Product Capacity: | 10TPH | Product Tanks: | 3xFRP Tanks |
---|---|---|---|
Product Technological Process: | SF-ACF-IXF-RO | Product Power And Voltage: | 19kW-380-415V, 50Hz |
Feed Water TDS Of The Device: | <2000 Ppm | Material: | Stainless Steel 304 Tank, UPVC Pipe |
Reverse Osmosis Membrane: | Filmtec/Hydranautics | Total Weight: | 620KG |
Size(LxWxH): | 280*85*190cm | Core Components Of The Plant: | Pump, RO Membrane,Tanks |
Other Configurations Of The Device: | Flower Meter & Pressure Gauge; LP&HP Switch;operational Status Indicators ;IC Control Unit & TDS Indicator | ||
Highlight: | 10TPH Reverse Osmosis Water Plant |
Product Description
10TPH FRP Tanks Reverse Osmosis Water Plant For Sea Water Desalination
Industrial Reverse Osmosis Water Purification System
The capacity of industrial water purification system ranges from 38m3/day to 7500m3/day. If you need a water purification system with less than this capacity, please refer to our commercial water treatment system.
All industrial reverse osmosis water treatment systems start from a booster pump to deliver raw water to a pretreatment tank. The size and number of pretreatment tanks depend on the capacity and can be changed. Also depending on the raw water source, the TDS (Total Dissolved Solids) material can be changed. At Chunke, if the water source is tap water or low TDS fresh water, we can use FRP, stainless steel 304 or 316. If the salt content and TDS are high, due to corrosion, we use FRP or carbon steel material for the pretreatment tank. Pretreatment includes sand media filter tank, activated carbon filter media tank and softener tank with ion exchange resin inside, which are very important for reverse osmosis water filtration.
Pretreatment is used to remove large suspended solids, iron, turbidity, unwanted color, bad taste, chlorine, sediment, organic pollutants, odor. In pre-treatment, we can control the industrial water purification flow manually or automatically.
The pre-treated water goes into the cartridge filter housing, we call it safety filter, most of the industrial water treatment system applications we use stainless steel 304 or 316 material, but if the water is very salty, like brackish water or seawater, we can use carbon steel, FRP or PVC plastic cartridge filter housing or bag filter housing. There are 1µm or 5 µm PP filters in the cartridge filter housing for industrial water treatment systems.
After the cartridge filter housing, the water goes into the membrane pressure vessel with a high pressure pump, you can choose the brand of the high pressure pump and it allows you to adjust your budget. Inside the membrane housing depends on the capacity, we have 4040 or 8040 membranes. Most of our projects use brands such as DOW Filmtec, Toray, Vontron, Hydranautics, LG for the reverse osmosis membrane.
The membrane in the industrial reverse osmosis water purification system is the most important part. They block substances larger than 0.001µm and with molecular weights up to 150-250 Dalton. It consists of impurities, particles, sugars, proteins, bacteria, dyes, organic and inorganic solids.
In addition, the RO water filtration system can add chemical agents such as antiscalants (antiscalants), antifouling agents, pH adjusters, sterilization disinfectants during pre-treatment or post-treatment.
We check the water analysis report of our customers, and sometimes due to scaling and fouling problems, we can use a CIP (cleaning in place) system, which can clean the membrane in the membrane housing and keep the membrane clean, thereby extending the life of the membrane.


Quality determines destiny, integrity determines success or failure
Specialized in: R&D, production and construction of reverse osmosis equipment, pure water equipment, softened water equipment, ultrapure water equipment, waste acid treatment equipment, cyanide highly toxic wastewater treatment and other products
Get rid of pesticides
- Benefits of pure water reverse osmosis equipment
- Remove suspended sediment
- Rust removal bleaching powder
- Remove heavy metals
- Remove microbial bacteria
The reverse osmosis membrane uses membrane separation technology to remove bacteria, viruses, heavy metal ions, etc. in the water to achieve pure water standards. The system desalination rate is over 98%.
Product name and basic parameters | Other Configuration | L(cm) | W(cm) | H(cm) | Weight(KG) |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 50 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 55 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 420 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 480 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 500 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 540 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 500 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 620 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 680 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 760 |
About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.
OUR CLIENTS
INDUSTRIES SERVED
PRODUCTION SYSTEM
Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.
Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.
Our FACTORY