• 4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well
  • 4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well
  • 4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well
  • 4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well
4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well

4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well

Product Details:

Place of Origin: China
Brand Name: Fenigal
Certification: CE
Model Number: Brackish Water Reverse Osmosis Water Plant

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: Negotiable
Packaging Details: standard export packing
Delivery Time: 5- 8 work days
Supply Ability: 60000 Units per Month
Get Best Price Contact Now

Detail Information

Device Capacity: 4TPH The Number And Material Of Tanks: 2xFRP Tanks
Device Process: SF-ACF-RO Device Power: 5.5kW-380-415V, 50Hz
Feed Water TDS Of The Device: <2000 Ppm Device Material: Stainless Steel 304 Tank, UPVC Pipe
RO Membrane: Filmtec/Hydranautics Device Weight: 360KG
Product Size(LxWxH): 280*85*170cm Core Components: Pump, RO Membrane,Tanks
Highlight:

4TPH Brackish Water Reverse Osmosis

,

Bore Well Brackish Water Reverse Osmosis

,

FRP Tanks Brackish Water Reverse Osmosis

Product Description

4TPH Pretreatment 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant



4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well 0


Parameter Table


Product name and basic parameters Other Configuration L(cm) W(cm) H(cm) Weight(KG)

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,     

installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 50

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 55

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 360

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 360

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 380

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 430

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 420

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 430

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 450

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 450

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 480

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 500

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 540

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 500

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 620

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 680

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 760


About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.

INDUSTRIES SERVED

4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well 1

PRODUCTION SYSTEM

Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.
Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.

Our FACTORY

4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well 2
4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well 34TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well 4
4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well 54TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well 6

Want to Know more details about this product
I am interested in 4TPH FRP Tanks Brackish Water Reverse Osmosis Water Plant For Bore Well could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.