• 3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant
  • 3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant
  • 3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant
  • 3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant

3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant

Product Details:

Place of Origin: China
Brand Name: Fenigal
Certification: CE
Model Number: Brackish Water Reverse Osmosis Water Plant

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: Negotiable
Packaging Details: standard export packing
Delivery Time: 5- 8 work days
Supply Ability: 60000 Units per Month
Get Best Price Contact Now

Detail Information

Capacity: 3TPH The Number And Material Of Tanks: 3xFRP Tanks
Process Of The Device: SF-ACF-IXF-RO Installed Power Of The Equipment: 5.5kW-380-415V, 50Hz
Feed Water TDS Of The Device: <2000 Ppm Materia Of The Device: Stainless Steel 304 Tank, UPVC Pipe
RO Membrane: Filmtec/Hydranautics Weight(KG): 340
Size(LxWxH): 260*80*170cm Components: Pump, RO Membrane,Tanks

Product Description

3TPH Pretreatment 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant

 

The working principle of a reverse osmosis device is based on the concept of osmotic pressure, which overcomes natural osmotic pressure by applying external pressure to achieve reverse osmosis of solvents. When a dilute solution and a concentrated solution are separated by a semi permeable membrane, the solvent in the dilute solution will naturally flow towards the concentrated solution side, forming osmotic pressure. In order to make the solvent flow from the concentrated solution side to the dilute solution side, a pressure greater than the osmotic pressure needs to be applied on the concentrated solution side, so that the solvent will flow in the opposite direction of natural permeation. This process is called reverse osmosis. ‌

The reverse osmosis device is mainly composed of a reverse osmosis membrane, which has a very small pore size and can effectively isolate impurities in water, such as charged ions, inorganic substances, colloidal particles, bacteria, and organic substances. After pre-treatment steps such as fine filters, granular activated carbon filters, and compressed activated carbon filters, the raw water is pressurized and passes through a reverse osmosis membrane to obtain pure water. Reverse osmosis devices are widely used in fields such as electronics, medicine, food, textiles, chemical engineering, and power generation, for the preparation of high-purity water, desalination of brackish water, and wastewater treatment.

The working process of a reverse osmosis device includes the following steps: firstly, the raw water is pretreated to remove impurities; Then, the pressurized water passes through a reverse osmosis membrane with a pore size of only 1/10000 μ m, which can effectively remove various impurities from the water; Finally, the water that passes through the membrane is pure water, while the concentrated solution that has not passed through is discharged.

 

Details Images
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 0
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 1
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 2
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 3
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 4

 

 
 
 
 
 
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 5
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 6
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 7
3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 8
 
Parameter Table
 
 
Product name and basic parameters Other Configuration L(cm) W(cm) H(cm) Weight(KG)

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,     

installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 50

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 55

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 360

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 360

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 380

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 430

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 420

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 430

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 450

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 450

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 480

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 500

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 540

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 500

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 620

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 680

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 760

 

About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.

OUR CLIENTS

3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 9

INDUSTRIES SERVED

3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 10

PRODUCTION SYSTEM

Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.
Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.

Our FACTORY

3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant 11
中国无锡芬尼格尔科技有限公司公司简介中国无锡芬尼格尔科技有限公司公司简介
中国无锡芬尼格尔科技有限公司公司简介中国无锡芬尼格尔科技有限公司公司简介

Want to Know more details about this product
I am interested in 3TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.