• 2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant
  • 2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant
  • 2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant
  • 2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant

2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant

Product Details:

Place of Origin: China
Brand Name: Fenigal
Certification: CE
Model Number: Brackish Water Reverse Osmosis Water Plant

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: Negotiable
Packaging Details: standard export packing
Delivery Time: 5- 8 work days
Supply Ability: 60000 Units per Month
Get Best Price Contact Now

Detail Information

Capacity: 2TPH Tank: 2xFRP Tanks
Process Of The Plant: SF-ACF-RO Voltage: 3.0kW-380-415V,50HZ
Feed Water TDS: <2000 Ppm Material: Stainless Steel 304 Tank, UPVC Pipe,
RO Membrane: Filmtec/Hydranautics Optional Weight(KG): 280
Size(LxWxH): 260*80*170cm Origin: China
Components: Pump, RO Membrane,Tanks

Product Description

2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant

 

What is reverse osmosis?

Reverse osmosis, often referred to as RO, is an advanced water purification method that was initially developed by the U.S. Navy to produce drinking water from sea water for submarine crews.

It is a membrane filtration technology that works by forcing water under pressure through the very tiny pores of a semi-permeable membrane. Modern reverse osmosis units for the home combine membrane technology with carbon and mechanical filtration to produce highly purified, great-tasting water.

How does it work?

In modern home units water, driven by normal city water pressure, flows first through a carbon pre-filter, which removes organic contaminants including chlorine and its by-products.

Next, it enters the reverse osmosis membrane, a very tight, sheet-like filter, that allows water to pass but rejects dissolved solids like sodium and impurities like lead and arsenic. Some of the water entering the unit is used to cleanse the membrane surface and flows to the the kitchen drain pipes.

The purified water is stored in a small storage tank until it is needed. When the ledge faucet mounted on the sink is opened, the purified water is forced by air pressure through another carbon filter, which gives it a final polish and from there to the ledge faucet.

(This is a simplified description of a three-stage RO unit. Additional stages like sediment filters and additional carbon filters can be included. The simplified description omits a few very essential parts like flow control devices, check valves, and an automatic shutoff devices that stops the inflow of water when the storage tank is full.)

Details Images
 
 
 
 
 
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 0
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 1
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 2
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 3
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 4
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 5
 
 
 
 

 

 

 

 
 
 

 

2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 6
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 7
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 8
2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 9
 
Parameter Table
 
 
Product name and basic parameters Other Configuration L(cm) W(cm) H(cm) Weight(KG)

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,     

installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 50

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 55

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)


SS304 skid-mount,

single pass membrane 4"x1,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220

Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)


SS304 skid-mount,

single pass membrane 4"x2,

installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230

Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)


SS304 skid-mount,

single pass membrane 4"x4,

installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235

Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280

Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)


SS304 skid-mount,

single pass membrane 8"x2,

installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340

Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)


SS304 skid-mount,

single pass membrane 8"x3,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 360

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 360

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380

Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)


SS304 skid-mount,

single pass membrane 8"x4,

installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 380

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400

Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)


SS304 skid-mount,

single pass membrane 8"x5,

installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 430

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 420

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 430

Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)


SS304 skid-mount,

single pass membrane 8"x6,

installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 450

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 450

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 480

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 500

Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)


SS304 skid-mount,

single pass membrane 8"x8,

installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 540

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 500

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 620

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 680

Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)


SS304 skid-mount,

single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;

*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 760

 

About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.

OUR CLIENTS

2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 10

INDUSTRIES SERVED

2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 11

PRODUCTION SYSTEM

Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.
Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.

Our FACTORY

2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant 12
中国无锡芬尼格尔科技有限公司公司简介中国无锡芬尼格尔科技有限公司公司简介
中国无锡芬尼格尔科技有限公司公司简介中国无锡芬尼格尔科技有限公司公司简介

Want to Know more details about this product
I am interested in 2TPH 3.0kW-380-415V 2xFRP Tanks Brackish Water Reverse Osmosis Water Plant could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.