DuPont SFP-2880 UF Membrane 77m2 for Industrial Water Treatment
Product Details:
| Place of Origin: | China |
| Brand Name: | Dupont |
| Certification: | CE |
| Model Number: | SFP-2880 |
| Document: | UF-IntegraTec-P-Series-PVDF...en.pdf |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 pc |
|---|---|
| Price: | Negotiable |
| Packaging Details: | standard export packing |
| Delivery Time: | 5- 8 work days |
| Payment Terms: | ,T/T |
| Supply Ability: | 60000 Units per Month |
|
Detail Information |
|||
| Flux Range: | 40–90 LMH (24–53 Gfd) At 25°C | Flow Rate Per Module: | 2.0–6.9 M³/hr (8.8–30.4 Gpm) |
|---|---|---|---|
| Temperature Limits: | 1–40°C (34–104°F) | Max Operating TMP: | 2.1 Bar (30.5 Psi) |
| Chemical Tolerance: | Withstands Up To 2,000 Mg/L NaOCl | Optimized Design: | 77m2 |
| Wide Application Range: | Suitable For Treating Surface Water, Seawater, Industrial Wastewater, And Municipal Effluents. | Membrane Type: | Industrial Grade Ultrafiltration Membrane Components |
| Highlight: | DuPont SFP-2880 UF membrane,industrial water treatment UF membrane,77m2 ultrafiltration membrane |
||
Product Description
DuPont UF SFP-2880 Industrial Grade Ultrafiltration Membrane Components
Product Overview
The DuPont UF SFP-2880 ultrafiltration membrane module delivers high-performance water treatment through advanced PVDF hollow fiber technology. Designed for industrial applications, it features a robust outside-in flow configuration that minimizes pretreatment requirements and reduces backwash volumes while handling feed water with high solids content.
Key Features
- High-Efficiency Filtration: 0.03 μm nominal pore size for effective removal of bacteria, viruses, colloids, and particulates, safeguarding downstream processes like reverse osmosis (RO).
- Durable PVDF Material: Hydrophilic hollow fibers with exceptional mechanical strength and chemical resistance (pH 2-11) ensure long membrane life and reliable operation.
- Optimized Design: 77 m² (829 ft²) membrane area provides maximum filtration capacity within a compact footprint, offering cost-effective system scaling.
- Wide Application Range: Suitable for treating surface water, seawater, industrial wastewater, and municipal effluents.
Technical Specifications
| Attribute | Value |
|---|---|
| Flux Range | 40–90 LMH (24–53 gfd) at 25°C |
| Flow Rate per Module | 2.0–6.9 m³/hr (8.8–30.4 gpm) |
| Temperature Limits | 1–40°C (34–104°F) |
| Max Operating TMP | 2.1 bar (30.5 psi) |
| Chemical Tolerance | Withstands up to 2,000 mg/L NaOCl |
| Membrane Area | 77m² |
Product Models
| Model | Type | Part # | Membrane Area (m²/ft²) | Volume (Liters/Gallons) | Weight (Kg/lbs) |
|---|---|---|---|---|---|
| SFP-2880 | Pretreatment | 280934 | 77 / 829 | 39 / 10.3 | 61 / 135 (empty) 100 / 220 (water filled) |
| SFD-2880 | NSF/ANSI 61 Drinking water | 324169 | 77 / 829 | 39 / 10.3 | 61 / 135 (empty) 100 / 220 (water filled) |
Operating Parameters
| Parameter | SI Units | US Units |
|---|---|---|
| Filtrate Flux @ 25ºC | 40-120 l/m²/hr | 24-70 gfd |
| Flow range | 3.1-9.3 m³/hr | 13.6 - 40.9 gpm |
| Temperature | 1-40ºC | 34-104ºF |
| Max. inlet module pressure (@ 20ºC) | 6.25 bar | 93.75 psi |
| Max. operating TMP | 2.1 bar | 30 psi |
| Max operating air scour flow | 12 nm³/hr | 7.1 scfm |
| Max backwash pressure | 2.5 bar | 36 psi |
Installation & Operation
Proper startup is critical to prevent membrane damage and achieve water quality goals. Before operation:
- Complete membrane preconditioning and module installation per technical manual
- Calibrate all instrumentation
- Flush system thoroughly to remove shipping solution
- Purge residual air from system
- Start manually at 60% design capacity
Note: NSF/ANSI 61 certified drinking water modules require specific conditioning procedures. Check local regulations before use.
For application cases, please visit: www.fgwater.com/Industries/
Want to Know more details about this product