Product Details:

Place of Origin: China
Brand Name: DOW
Certification: CE
Model Number: SFP-2860

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: Negotiable
Packaging Details: standard export packing
Delivery Time: 5- 8 work days
Supply Ability: 60000 Units per Month
Get Best Price Contact Now

Detail Information

The Module Flow Range: 2.0 – 6.1 M3 /hr The Module Flow Range Membrane Area: 51 M²
Module Nominal Pore Diameter: 0.03 µm The Module Material: PVDF
Diameter Of This Model: 8 Inch Flow Direction Settings: External Pressure Structure, Dead End Filtration
Component NaOCl (max.) Of This Model: 2,000 Mg/L The Max Backwash Pressure: 2.5 Bar
Component Filtration Accuracy: 0.01-0.1μm Operating Pressure: 2.5M
Component Max. Operating TMP: 2.1 Bar Component Turbidity (max.): 300 Ntu
Component Advantages: High-Capacity, Fouling-Resistant Application: Industrial & Municipal
Highlight:

Industrial DOW UF SFP-2860

,

High-Capacity DOW UF SFP-2860

,

Municipal DOW UF SFP-2860

Product Description

DOW™ UF SFP-2860: High-Capacity, Fouling-Resistant for Industrial & Municipal

The DOW™ UF SFP-2860 Ultrafiltration Membrane represents a breakthrough in water treatment technology, delivering superior filtration performance with unmatched efficiency and reliability. Engineered for demanding industrial and municipal applications, this advanced membrane system combines cutting-edge materials science with innovative design to provide exceptional water quality while reducing operational costs.

​Key Features & Benefits:​

  1. ​Enhanced Filtration Performance​
  • 0.02 micron pore size for effective removal of bacteria, viruses, and suspended solids
  • 99.99% pathogen rejection rate

  • Consistent product water quality with SDI <3
  1. ​Optimized Energy Efficiency​
  • Low transmembrane pressure operation (0.5-1.5 bar)
  • 30% energy savings compared to conventional UF membranes
  • High permeability design reduces pumping requirements
  1. ​Advanced Anti-Fouling Technology​
  • Proprietary hydrophilic membrane surface
  • Reduced cleaning frequency (up to 50% less than standard membranes)
  • Exceptional tolerance to high turbidity (up to 500 NTU)
  1. ​Robust Construction & Longevity​
  • Reinforced PVDF hollow fiber membrane
  • Withstands chlorine exposure up to 500,000 ppm-hours
  • 5+ year lifespan with proper maintenance
  1. ​Operational Flexibility​
  • Wide pH tolerance range (2-11 for cleaning, 4-10 for operation)
  • Temperature resistance up to 40°C
  • Multiple configuration options (pressurized/submerged)

​Technical Specifications:​

  • Membrane Material: Polyvinylidene fluoride (PVDF)
  • Fiber Diameter: 1.0/1.7 mm (inner/outer)
  • Maximum Operating Pressure: 3.0 bar
  • Typical Flux Rate: 50-100 LMH (L/m²/h)
  • Module Dimensions: Customizable (standard 8" diameter)

​Applications:​

  • Pretreatment for reverse osmosis systems
  • Surface water treatment for potable use
  • Industrial process water purification
  • Wastewater reuse and recycling
  • Seawater pretreatment for desalination

​Why Choose DOW™ UF SFP-2860?​
The SFP-2860 sets a new standard in ultrafiltration technology by combining Dow's material science expertise with practical engineering solutions. Its superior fouling resistance and energy-efficient operation significantly reduce lifecycle costs, while the robust construction ensures reliable performance in challenging water conditions. Whether for large-scale municipal projects or specialized industrial applications, the SFP-2860 delivers consistent, high-quality filtration results.

​Certifications & Compliance:​

  • NSF/ANSI 61 Certified
  • ISO 9001 Quality Management System
  • CE Marked
  • Meets AWWA and EPA standards

For optimal performance, we recommend pairing the SFP-2860 with Dow's complete ultrafiltration system solution, including skid-mounted modules, backwash systems, and chemical cleaning stations. Our technical support team can provide customized system design and operational guidance to maximize your investment.

 

 

DOW™ UF SFP-2860 High-Capacity Fouling-Resistant  For Industrial Municipal 0

Product Specifications

 

Membrane area

 

Module volume

Weight

(empty/ water filled)

Model Type Part # m2 ft2 Liters Gallons Kg lbs
SFP-2860 Pretreatment 280933 51 549 35 9.3 48/83 106/183
SFD-2860

NSF/ANSI 61

Drinking water

324168 51 549 35 9.3 48/83 106/183

 

Figure 1: SFP and SFD 2860 (8-inch diameter)

 

DOW™ UF SFP-2860 High-Capacity Fouling-Resistant  For Industrial Municipal 1

Figure 2

DOW™ UF SFP-2860 High-Capacity Fouling-Resistant  For Industrial Municipal 2

Properties   Length     Diameter Width  
Units L L1 L2 L3 D W1 W2
SI (mm) 1860 1500 1630 1820 225 180 342

Operating Parameters

  SI units US units
Filtrate Flux @ 25ºC 40-120 l/m2/ hr 24-70 gfd
Flow range 2.0 6.1 m3/hr 9.2 26.7 gpm
Temperature 1-40ºC 34-104ºF
Max. inlet module pressure (@ 20ºC) 6.25 bar 93.75 psi
Max. operating TMP 2.1 bar 30 psi
Max operating air scour flow 12 nm3/hr 7.1 scfm
Max backwash pressure 2.5 bar 36 psi
Operating pH 2- 11
NaOCl (max.) 2,000 mg/L
TSS (max.) 100 mg/L
Turbidity (max.) 300 ntu
Particle size (max.) 300 µ
Flow configuration Outside in, dead end flow
Expected filtrate turbidity ≤0.1 NTU
Expected filtrate SDI ≤2.5

Important information

Proper start-up of a UF system is indispensable for preparing the membranes for operational service and preventing membrane damage. Adhering to the correct start-up sequence also contributes to ensuring that the operating parameters of the system conform to the design specifications, thereby enabling the attainment of system water quality and productivity targets. Before commencing the system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration, and other system checks should be accomplished. Kindly refer to the product technical manual.

Operation guidelines

Avoid any sudden pressure fluctuations during start-up, shutdown, cleaning or other processes to prevent potential membrane damage. Flush the UF system to eliminate the shipping solution before start-up. Remove the residual air from the system before start-up. Manually initiate the equipment. Aim for a permeate flow of 60% of the design during the initial operations. Depending on the application, the permeate obtained from the initial operations should be disposed of. Please refer to the product technical manual.

Regulatory note

NOTICE: NSF/ANSI 61 certified drinking water modules demand specific conditioning procedures before generating potable water. Please refer to the flushing section of the product technical manual for detailed procedures. Drinking water modules might be subject to additional regulatory constraints in certain countries. Please verify local regulatory guidelines and the application status before usage and sale.

The utilization of this product does not inevitably ensure the elimination of cysts and pathogens from water. Effective reduction of cysts and pathogens depends on the complete system design as well as the operation and maintenance of the system.

 

Notice: No inference should be made regarding the absence of infringement of any patent owned by Dow or others. As the use conditions and applicable laws may vary from one location to another and may change over time, the Customer is accountable for determining whether the products and the information in this document are suitable for the Customer's use and for ensuring that the Customer's workplace and disposal practices comply with applicable laws and other governmental enactments. The product presented in this literature might not be available for sale and/or available in all geographical areas where Dow is represented. The claims made might not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to "Dow" or the "Company" signify the Dow legal entity selling the products to the Customer unless otherwise explicitly noted. NO WARRANTIES ARE PROVIDED; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED.

For detailed parameters, please visit:

 

DOW™ UF SFP-2860 High-Capacity Fouling-Resistant  For Industrial Municipal 3 DOW™ UF SFP-2860 High-Capacity Fouling-Resistant  For Industrial Municipal 4
DuPont Ultrafiltration SFD 2860 XP IntegraFlux Module DuPont SFP 2860 XP IntegraFlux Ultrafiltration Module

About Us

FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.


HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.

Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.

OUR CLIENTS

DOW™ UF SFP-2860 High-Capacity Fouling-Resistant  For Industrial Municipal 5

PRODUCTION SYSTEM

Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.

Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.

Want to Know more details about this product
I am interested in DOW™ UF SFP-2860 High-Capacity Fouling-Resistant For Industrial Municipal could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.