Product Details:

Place of Origin: China
Brand Name: Fenigal
Certification: CE
Model Number: Brackish Water Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: Negotiable
Packaging Details: standard export packing
Delivery Time: 5- 8 work days
Supply Ability: 60000 Units per Month
Get Best Price Contact Now

Detail Information

Plant Productivity: 250L/H Plant Installed Power: 1.7kW-220-240V, 50Hz
Plant Feed Water TDS: <2000 Ppm Plant Process: Sediment Filters-RO
Plant Water Pipes Material: UPVC Water Pipes RO Membrane Optional: Filmtec/Hydranautics
Plant Weight: 50 Plant Size(LxWxH-cm): 60*50*145
Highlight:

250 LPH Commercial Reverse Osmosis Plant

,

Drinking Water Commercial Reverse Osmosis Plant

,

98%~99% Desalination Rate Reverse Osmosis Plant

Product Description

250 LPH Commercial Reverse Osmosis Plant For Drinking Water

 

Products Description
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 0
 
Reverse Osmosis(RO) System
 
Reverse Osmosis (RO) is a water treatment process that removes contaminants from water by using pressure to force water molecules through asemipermeable membrane.
 
During this process, the contaminants are filtered out and flushed away, leaving clean, delicious drinking water.
Details Images
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 1
Working Process:
Raw water pump→ mechanical filter(quartz sand filter)→ activated carbon filter→ security filter→ high pressure pump →reverse osmosis system→ Ozone sterilizer (UV sterilizer).
 
1. Water tank: storage of tap water, to solve the problem of insufficient tap water pressure and the back booster pump due to the impact of insufficient water, reduce the failure rate
2. Booster pump: equipped with a stainless steel pump, to provide sufficient pressure for subsequent filtration
3. Quartz sand filter: mainly remove the mud, suspended solids and large particles in the tap water
4. Carbon filter: mainly remove organic substances, residual chlorine and odor in tap water
5. Water softener filter: mainly remove the calcium and magnesium in tap water, reduce the hardness of water
6. Security filter: further filtration, protection of reverse osmosis membrane
7. High pressure pump: provide enough pressure for reverse osmosis system
8. Reverse osmosis unit: the core part of pure water equipment, the production of high-purity water.
9. Pure water tank: storage pure water, can change the size of the water tank,after the below process,The water result is pure enough for different application.
 
You can choose frp or stainsteel tank filter system and with or without pre-filter.We can customize the system according to your requirements.
Advantages
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 2
Reverse osmosis equipment belongs to physical desalting method, which has many advantages.
1) Non-phase-change physical method was used to desalinate and purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can remove colloid, organics, bacteria, virus and all kinds of heavy metals in water at the same time.
3) With water pressure as the driving force, energy consumption is the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination of chemical waste liquid, no environmental pollution, and the recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with automatic protection function.
6) The system is simple, easy to operate, and the water quality is stable.
7) Equipment covers small area, compact structure, reliable operation and high water quality.
Product Paramenters
Frame material
304 stainless steel
Pipeline material
food grade PVC pipe
Applicable water pressure
0.2-0.5MPA
Applicable water source
<1200ppm
Applicable temperature
0-38 ° C
Power supply
AC220V/380V
Applications
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 3
RO system is widely used in water treatment, purification for tap water, well water, underground water, borehole salty water, brackish water and seawater, pure water and ultra-pure water production. Application area such as, food processing, bottled drinking water, home use drinking water, power stations, electronic industries, cosmetics production, pharmaceuticals manufactories, and medical treatment(such as hemodialysis). It is a key equipment for pure water plant and ultrapure water equipment.
Customer Photos
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 4
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 5
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 6
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 7
98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 8

 

All optional configurations:

Product name and basic parameters Other Configuration L(cm) W(cm) H(cm) Weight(KG)
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD),
SS304 skid-mount, single pass membrane 4"x1, installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 50
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD),
SS304 skid-mount, single pass membrane 4"x2, installed power 1.7kW-220-240V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: sediment filters-RO
*with 3 stage sediment filters;
*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
60 50 145 55
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD),
SS304 skid-mount, single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD),
SS304 skid-mount, single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-IXF-RO
*pretreatment: 3 FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD),
SS304 skid-mount, single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD),
SS304 skid-mount, single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD),
SS304 skid-mount, single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD),
SS304 skid-mount, single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD),
SS304 skid-mount, single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 220
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD),
SS304 skid-mount, single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 240
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD),
SS304 skid-mount, single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD),
SS304 skid-mount, single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD),
SS304 skid-mount, single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process: SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 230
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD),
SS304 skid-mount, single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 78 170 250
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 235
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 255
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 280
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD),
SS304 skid-mount, single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD),
SS304 skid-mount, single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 320
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD),
SS304 skid-mount, single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD),
SS304 skid-mount, single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 340
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD),
SS304 skid-mount, single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
260 80 170 360
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD),
SS304 skid-mount, single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 360
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD),
SS304 skid-mount, single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD),
SS304 skid-mount, single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 380
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD),
SS304 skid-mount, single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD),
SS304 skid-mount, single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 380
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD),
SS304 skid-mount, single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD),
SS304 skid-mount, single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 400
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD),
SS304 skid-mount, single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
160 85 170 430
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD),
SS304 skid-mount, single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 400
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD),
SS304 skid-mount, single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 420
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD),
SS304 skid-mount, single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 430
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD),
SS304 skid-mount, single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 170 450
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD),
SS304 skid-mount, single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 450
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD),
SS304 skid-mount, single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 480
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD),
SS304 skid-mount, single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 500
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD),
SS304 skid-mount, single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 180 540
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD),
SS304 skid-mount, single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 500
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD),
SS304 skid-mount, single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x FRP tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 620
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD),
SS304 skid-mount, single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-RO
*pretreatment: 2x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 680
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD),
SS304 skid-mount, single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional;
feed water TDS<2000ppm;
*process:SF-ACF-IXF-RO
*pretreatment: 3x SS304 tanks;

*uPVC water pipes;
*flower meter & pressure gauge; *LP&HP switch;operational status indicators
*IC control unit & TDS indicator
*Filmtec/Hyranautics RO membranes optional
280 85 190 760

 

About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.

OUR CLIENTS

98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 9

INDUSTRIES SERVED

98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 10

PRODUCTION SYSTEM

Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.
Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.

Our FACTORY

98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water 11
中国无锡芬尼格尔科技有限公司公司简介中国无锡芬尼格尔科技有限公司公司简介
中国无锡芬尼格尔科技有限公司公司简介中国无锡芬尼格尔科技有限公司公司简介

Want to Know more details about this product
I am interested in 98%~99% Desalination Rate 250 LPH Commercial Reverse Osmosis Plant For Drinking Water could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.