5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant
Product Details:
Place of Origin: | China |
Brand Name: | Fenigal |
Certification: | CE |
Model Number: | Brackish Water Reverse Osmosis Water Plant |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 pc |
---|---|
Price: | Negotiable |
Packaging Details: | standard export packing |
Delivery Time: | 5- 8 work days |
Supply Ability: | 60000 Units per Month |
Detail Information |
|||
Product Capacity: | 5TPH | The Number And Material Of Tanks: | 3xSS304 Tanks |
---|---|---|---|
Product Process: | SF-ACF-IXF-RO | Product Power: | 7.4kW-380-415V, 50Hz |
Feed Water TDS Of The Device: | <2000 Ppm | Product Material: | Stainless Steel 304 Tank, UPVC Pipe |
Membrane Optional: | Filmtec/Hydranautics | Product Weight: | 430KG |
Product Size(LxWxH): | 160*85*170cm | Core Components Of The Plant: | Pump, RO Membrane,Tanks |
Other Configurations Of The Product: | Flower Meter & Pressure Gauge; LP&HP Switch;operational Status Indicators ;IC Control Unit & TDS Indicator | ||
Highlight: | 5TPH Brackish Water Reverse Osmosis,3xSS304 Tanks Brackish Water Reverse Osmosis,7.4kW Brackish Water Reverse Osmosis |
Product Description
5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant
Introduction for RO system each stages:
- Quartz Sand filter:
The quartz sanf filter is widely used in drinking water treatment to remove different types of particles, such as suspended solids (turbidity), colloidal compounds and etc. - Active Carbon filter
The active-carbon filter is commonly used for removal of organic substance and heavy metal element, suspended solids, residual chlorine and etc. It can effectively reduce the level of COD and improve the taste of water. - Softener (Optional if need):
Ion exchange resin is used in water softening system for Ca+,Mg+ and other cation exchange . To prevent undissolved salt from depositing in the surface of reverse osmosis membrane ,the resin which ensures well permeable ability of membrane module after it works a long time and extends
lifetime of membranes , enhances quality stability of ro purified water . (If raw water hardness is too high, softener is recommended to add to the system)
- Cartridge filter:
The cartridge filter is most commonly used for treat water. The whole system adopts one set of stainless filter. filtering the vast majority of particles in the water, which eases the load of RO membrane. This process of filtration benefits to the filter cartridge and prolongs its lifetime in the system. - Reverse Osmosis System( RO)
RO system is the key part for the water treatment system, which is widely used to make the pure water and drinking water. RO membrane removes many types of large molecules and ions from solutions by applying pressure to the solution when it is on one side of a selective membrane. The Virus, bacteria and solids is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the other side.
Features:
1. Can run and produce water continuously, highly automatic.
2. No need chemical to regeneration,easy operation and maintainance.
3. RO reverse osmosis system uses first-line membrane.
4. Automatic switch on when lack of water,and switch off when no water or full of water.
5. RO membrane auto wash and reduce the pollution speed.
6. Low-pressure switch protects high-pressure pump from damage cause by water supply stops.
7. Production water condutivity meter monitors water quality online contionuosly.
8. Input water and dense water pressure meters, monitor the water treatment machinery differential pressure and remind the time of washing.
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 1](http://sc04.alicdn.com/kf/H86b7af3df5584db7bf529bc87ad4b1e6L/276048308/H86b7af3df5584db7bf529bc87ad4b1e6L.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 2](http://sc04.alicdn.com/kf/H2e9e41dae4684713be2c4d8b3262ef41f/276048308/H2e9e41dae4684713be2c4d8b3262ef41f.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 3](http://sc04.alicdn.com/kf/H9a7b9b089c044d8c8bdba5e6d592f248j/276048308/H9a7b9b089c044d8c8bdba5e6d592f248j.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 4](http://sc04.alicdn.com/kf/Hbbf5d8f2daa84652a792c1b64cee9dfcf/276048308/Hbbf5d8f2daa84652a792c1b64cee9dfcf.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 5](http://sc04.alicdn.com/kf/Haa56fe7e28a7498e9e9ba7d7a092aff9R/276048308/Haa56fe7e28a7498e9e9ba7d7a092aff9R.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 6](http://sc04.alicdn.com/kf/Hcedfe1f81b814e379777f1ae9738f865K/276048308/Hcedfe1f81b814e379777f1ae9738f865K.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 7](http://sc04.alicdn.com/kf/H2d49074ddf1442df8bc3f321fe605769X/276048308/H2d49074ddf1442df8bc3f321fe605769X.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 8](http://sc04.alicdn.com/kf/H78c7bae35ea141e486ec84f20bc07bf6K/276048308/H78c7bae35ea141e486ec84f20bc07bf6K.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 9](http://sc04.alicdn.com/kf/H49967111414f41d596534d9f29185b75G/276048308/H49967111414f41d596534d9f29185b75G.jpg)
![5TPH 7.4kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant 10](http://sc04.alicdn.com/kf/H6bb741dbb0be476c8377a8a697cbb318U/276048308/H6bb741dbb0be476c8377a8a697cbb318U.jpg)
Product name and basic parameters | Other Configuration | L(cm) | W(cm) | H(cm) | Weight(KG) |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 50 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 55 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 420 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 480 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 500 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 540 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 500 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 620 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 680 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 760 |
About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.
OUR CLIENTS
INDUSTRIES SERVED
PRODUCTION SYSTEM
Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.