4TPH 5.5kW-380-415V 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant
Product Details:
Place of Origin: | China |
Brand Name: | Fenigal |
Certification: | CE |
Model Number: | Brackish Water Reverse Osmosis Water Plant |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 pc |
---|---|
Price: | Negotiable |
Packaging Details: | standard export packing |
Delivery Time: | 5- 8 work days |
Supply Ability: | 60000 Units per Month |
Detail Information |
|||
Capacity Of The Device: | 4TPH | The Number And Material Of Tanks: | 3xFRP Tanks |
---|---|---|---|
Process: | SF-ACF-IXF-RO | Power: | 5.5kW-380-415V, 50Hz |
Feed Water TDS Of The Device: | <2000 Ppm | Material: | Stainless Steel 304 Tank, UPVC Pipe |
RO Membrane: | Filmtec/Hydranautics | Weight: | 380KG |
Product Size(LxWxH): | 280*85*170cm | Core Components: | Pump, RO Membrane,Tanks |
Other Configurations: | Flower Meter & Pressure Gauge; LP&HP Switch;operational Status Indicators ;IC Control Unit & TDS Indicator |
Product Description
4TPH Pretreatment 3xFRP Tanks Brackish Water Reverse Osmosis Water Plant
Reverse osmosis is a modern new pure water treatment technology that uses reverse osmosis elements to improve the purity of water and remove impurities and salts in water. This technology adjusts the pressure on both sides of the reverse osmosis membrane, compresses the raw water through the membrane, and moves the water molecules with low salt concentration from the low concentration area to the high concentration area, thereby achieving effective separation of salts and impurities in the water.
In the reverse osmosis process, by controlling the pressure difference on both sides of the membrane, water molecules are forced to pass through the microporous membrane to form high-purity permeable water, while the remaining high-concentration impurities are rejected and discharged with the wastewater. When the osmotic pressure equilibrium state of the liquid is reached, the reverse osmosis process also reaches a stable state.
When the pressure on the salty water side is higher than the osmotic pressure on the other side, reverse osmosis flow is triggered, and this reverse flow constitutes the basis of the reverse osmosis process. This process not only effectively removes salt and pollutants in the water, but also greatly improves the water quality, so that the water meets the standards for drinking or industrial water, and provides reliable pure water resources for various industries. Reverse osmosis technology plays a vital role in the field of water treatment and has made positive contributions to improving water quality and protecting the environment.
Product name and basic parameters | Other Configuration | L(cm) | W(cm) | H(cm) | Weight(KG) |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 50 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 55 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 420 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 480 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 500 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 540 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 500 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 620 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 680 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 760 |
About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.
OUR CLIENTS
INDUSTRIES SERVED
PRODUCTION SYSTEM
Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.
Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.
Our FACTORY