2TPH 3.0kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant
Product Details:
Place of Origin: | China |
Brand Name: | Fenigal |
Certification: | CE |
Model Number: | Brackish Water Reverse Osmosis Water Plant |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 pc |
---|---|
Price: | Negotiable |
Packaging Details: | standard export packing |
Delivery Time: | 5- 8 work days |
Payment Terms: | MoneyGram |
Supply Ability: | 60000 Units per Month |
Detail Information |
|||
Capacity: | 2TPH | The Number And Material Of Tank: | 3xSS304 Tanks |
---|---|---|---|
Process Of The Device: | SF-ACF-IXF-RO | Electrical Power: | 3.0kW-380-415V,50HZ |
Feed Water TDS: | <2000 Ppm | Material: | Stainless Steel 304 Tank, UPVC Pipe |
RO Membrane: | Filmtec/Hydranautics | Weight(KG): | 320 |
Size(LxWxH): | 260*80*170cm | Components: | Pump, RO Membrane,Tanks |
Product Description
2TPH 3.0kW-380-415V 3xSS304 Tanks Brackish Water Reverse Osmosis Water Plant
RO reverse osmosis technology has significant advantages in the field of water treatment, which are mainly reflected in the following aspects:
1. High desalination efficiency and pure water quality: RO reverse osmosis membrane can effectively intercept pollutants such as dissolved salts, organic matter, microorganisms, heavy metal ions, etc. in water with its fine microporous structure and selective permeability, achieving a desalination rate of more than 95%, ensuring the pure water quality of the effluent.
2. Energy saving and environmental protection: The RO reverse osmosis process does not need to undergo phase change, so the energy consumption is significantly reduced. Although additional pump pressure is required to overcome the osmotic pressure, the overall energy consumption is still at a low level, which is in line with the environmental protection concept of energy saving and consumption reduction.
3. Mild operating conditions: The reverse osmosis membrane separation process is carried out at room temperature, avoiding the problem of heat-sensitive substances that may be destroyed by high-temperature distillation. It is particularly suitable for the preparation of temperature-sensitive biological products, pharmaceutical ingredients, and electronic ultrapure water.
4. Compact system and simple operation: The RO reverse osmosis equipment has a compact structure design and a small footprint, which is easy to install in various space environments. At the same time, the technology is easy to realize automatic control, reduce the need for manual intervention, and improve operational stability.
5. Moderate maintenance cost: Although the reverse osmosis membrane has a certain service life and needs to be replaced regularly, its maintenance cost is more economical than other complex water treatment facilities. Some membrane elements can also restore performance through chemical cleaning, further saving operating costs.
Professional water treatment equipment production base
Factory direct sales |Support customization |Lifetime Warranty |Worry-free after-sale service
You need a water purification device like this
Application scope
- Hotel/company water treatment
- Food production line water treatment
- Pharmaceutical/Laboratory Water Treatment
- Residential water treatment
- Water treatment in livestock farms
Product name and basic parameters | Other Configuration | L(cm) | W(cm) | H(cm) | Weight(KG) |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 50 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-220-240V, 50Hz; other voltages optional; |
*process: sediment filters-RO *with 3 stage sediment filters; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
60 | 50 | 145 | 55 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3 FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 250L/h (1,600 GPD)
single pass membrane 4"x1, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 220 |
Reverse Osmosis Water Plant Permeate 500L/h (3,200 GPD)
single pass membrane 4"x2, installed power 1.7kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 240 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process: SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 230 |
Reverse Osmosis Water Plant Permeate 1TPH (6,400 GPD)
single pass membrane 4"x4, installed power 2.1kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 78 | 170 | 250 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 235 |
Reverse Osmosis Water Plant Permeate 1.5TPH (9,600 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 255 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 280 |
Reverse Osmosis Water Plant Permeate 2TPH (12,800 GPD)
single pass membrane 8"x2, installed power 3.0kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 320 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 340 |
Reverse Osmosis Water Plant Permeate 3TPH (19,200 GPD)
single pass membrane 8"x3, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
260 | 80 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 360 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 4TPH (25,600 GPD)
single pass membrane 8"x4, installed power 5.5kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 380 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 5TPH (32,000 GPD)
single pass membrane 8"x5, installed power 7.4kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
160 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 400 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 420 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 430 |
Reverse Osmosis Water Plant Permeate 6TPH (38,400 GPD)
single pass membrane 8"x6, installed power 7.9kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 170 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 450 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 480 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 500 |
Reverse Osmosis Water Plant Permeate 8TPH (51,200 GPD)
single pass membrane 8"x8, installed power 14kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 180 | 540 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 500 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x FRP tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 620 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-RO *pretreatment: 2x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 680 |
Reverse Osmosis Water Plant Permeate 10TPH (64,000 GPD)
single pass membrane 8"x10, installed power 19kW-380-415V, 50Hz; other voltages optional; |
*process:SF-ACF-IXF-RO *pretreatment: 3x SS304 tanks; *uPVC water pipes; *flower meter & pressure gauge; *LP&HP switch;operational status indicators *IC control unit & TDS indicator *Filmtec/Hyranautics RO membranes optional |
280 | 85 | 190 | 760 |
About Us
FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.
HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.
Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.
OUR CLIENTS
INDUSTRIES SERVED
PRODUCTION SYSTEM
Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.
Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.
Our FACTORY