9000GPD Salt Water RO System
Product Details:
Place of Origin: | China |
Brand Name: | Fenigal/OEM |
Certification: | CE/UL/NSF etc. |
Model Number: | HR-1.5k~9k |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | Standard Export Wood Crate/Carton or Naked wrapped by film |
Delivery Time: | 15~30 days |
Payment Terms: | T/T, Western Union, Paypal etc. |
Supply Ability: | 50 set per month |
Detail Information |
|||
Technology: | Brackish Water Reverse Osmosis | Design: | Skid Mount |
---|---|---|---|
Recovery Rate: | 15~65% | Feed TDS/ppm: | <10,000 |
Water Temp.: | 5~35˚C | PH: | 4~9 |
TSS/mg/L: | <5 | Silt Density Index: | <3 |
Free Chlorine Mg/L: | 0 | Dissolved Iron Mg/L: | <0.1 |
Warranty: | 1 Year | Material: | SS304/SS316L,carbon Steel |
Capacity: | 0.5-100m3/h | Voltage: | 380V,415V,220V,can Be Customized |
Application: | Water Purification,Filtration,pharmceutical,drinking Water,food | Size: | Depends,1750*550*1650mm |
Type: | Reverse Osmosis System | Function: | Water Purifying, Desalination |
Desalination Rate: | 99%,99.7% | Control: | Electronic,Manual/PLC |
Ro Membrane: | Hydranautics Or DOW,4040 | Pump: | CNP / Grundfos,CNP |
Highlight: | 9000GPD salt water ro system,10000ppm salt water ro system,9000GPD Brackish Water System |
Product Description
Brackish water reverse osmosis system HR1,500GPD~9,000GPD TDS<10,000ppm
HR – Series Reverse Osmosis Systems are designed for durability and superior performance and are well–suited for treating well water and surface water containing dissolved solids up to 10,000 ppm. The HR – Series is specifically designed with a compact frame to fit into small areas such as utility rooms. HR – Series Reverse Osmosis Systems have been engineered for capacities ranging from 1,500 to 9,000 gallons per day. These systems include a computer processor with standard control functions for dual TDS monitoring, low pressure monitoring with alarm, pre–treatment lockout, feed flush and tank level input. These models feature high quality components such as a stainless steel multi–stage high pressure pump, low energy membrane elements, membrane housings rated at 450 psi and a cartridge housing with a 5 – micron sediment pre–filter. Options available for the HR – Series include permeate divert, variable frequency drive, a chemical injection system and a clean–in–place system.
Benefits
Fully Equipped and Customizable
Expandable and Skid Mounted
Decreased Size of Dimensional Footprint
Components Easily Accessible
Pre–Plumbed, Wired and Assembled
Individually Tested and Preserved
Low Operation and Maintenance Costs
Easy Maintenance and Servicing
1–Year Limited Warranty
Features
Microcomputer Controller LCD Backlit Display Pre–Treatment Lockout Tank Level Input High Pressure Monitoring with Alarm Low Pressure Monitoring with Alarm Dual TDS Monitoring Feed Flush Permeate and Concentrate Flow Meters Pre–Filter 0 – 100 psi Panel Mounted Glycerin Filled Gauges Glycerin–Filled Pump Discharge and Concentrate Pressure Gauges Micron Sediment Pre–Filter |
Single O–Ring Heavy–Duty Filter Housing Filmtec® LCLE Low Energy Membrane Elements FRP – Series Membrane Housings – 450 psi Vertical Multi–Stage Stainless Steel Booster Pump Plastomatic Feed Solenoid Valve Feed Low Pressure Switch Pump High Pressure Switch Clean–in–Place (CIP) Ports Victaulic® Style Fittings Permeate Sample Ports High Pressure Stainless Steel Tubing and Fittings White Powder Coated Aluminum Frame |
Options and Upgrades
Variable Frequency Drive (VFD) n Filmtec® LCHR Membrane Elements n Pump Pressure Relief Valve n Blending Valve n Permeate Divert Valve n Permeate Flush |
Chemical Pump Outlet pH Controller ORP Controller n High Pressure Tank Switch n Caster Wheels n Wooden Shipping Crate |
Array Specifications
Model | Vessel Array | Vessel Size | Vessel Quantity | Membrane Size | Membrane Quantity |
HR – 1140 | 1 | 4040 | 1 | 4040 | 1 |
HR – 2140 | 1:1 | 4040 | 2 | 4040 | 2 |
HR – 3140 | 1:1:1 | 4040 | 3 | 4040 | 3 |
HR – 4140 | 1:1:1:1 | 4040 | 4 | 4040 | 4 |
HR – 5140 | 1:1:1:1:1 | 4040 | 5 | 4040 | 5 |
HR – 6140 | 1:1:1:1:1:1 | 4040 | 6 | 4040 | 6 |
Product Specifications
Models | HR – 1140 | HR – 2140 | HR – 3140 | HR – 4140 | HR – 5140 | HR – 6140 |
Design | ||||||
Configuration | Single Pass | Single Pass | Single Pass | Single Pass | Single Pass | Single Pass |
Feedwater Source† | TDS <10,000 ppm | TDS <10,000 ppm | TDS <10,000 ppm | TDS <10,000 ppm | TDS <10,000 ppm | TDS <10,000 ppm |
Standard Recovery Rate % | 15 – 25 | 30 – 40 | 40 – 50 | 40 – 55 | 40 – 60 | 40 – 65 |
Rejection and Flow Rates | ||||||
Nominal Salt Rejection % | 99.2 | 99.2 | 99.2 | 99.2 | 99.2 | 99.2 |
Permeate Flow (gpm / lpm) | 1.04 / 3.94 | 2.08 / 7.89 | 3.13 / 11.83 | 4.17 / 15.77 | 5.21 / 19.72 | 6.25 / 23.66 |
Minimum Feed Flow (gpm / lpm) | 4.04 / 15.30 | 5.08 / 19.20 | 6.13 / 23.20 | 7.17 / 27.10 | 8.21 / 31.10 | 9.25 / 35.00 |
Maximum Feed Flow (gpm / lpm) | 14.00 / 53.00 | 14.00 / 53.00 | 14.00 / 53.00 | 14.00 / 53.00 | 14.00 / 53.00 | 14.00 / 53.00 |
Minimum Concentrate Flow (gpm / lpm) | 3.00 / 11.36 | 3.00 / 11.36 | 3.00 / 11.36 | 3.00 / 11.36 | 3.00 / 11.36 | 3.00 / 11.36 |
Connections | ||||||
Feed (in) | 1 FNPT | 1 FNPT | 1 FNPT | 1 FNPT | 1 FNPT | 1 FNPT |
Permeate (in) | 3/4 FNPT | 3/4 FNPT | 3/4 FNPT | 1 FNPT | 1 FNPT | 1 FNPT |
Concentrate (in) | 3/4 FNPT | 3/4 FNPT | 3/4 FNPT | 1 FNPT | 1 FNPT | 1 FNPT |
CIP (in) | 3/4 FNPT | 3/4 FNPT | 3/4 FNPT | 3/4 FNPT | 3/4 FNPT | 3/4 FNPT |
Membranes | ||||||
Membrane Per Vessel | 1 | 1 | 1 | 1 | 1 | 1 |
Membrane Quantity | 1 | 2 | 3 | 4 | 5 | 6 |
Membrane Size | 4040 | 4040 | 4040 | 4040 | 4040 | 4040 |
Vessels | ||||||
Vessel Array | 1 | 1:1 | 1:1:1 | 1:1:1:1 | 1:1:1:1:1 | 1:1:1:1:1:1 |
Vessel Quantity | 1 | 2 | 3 | 4 | 5 | 6 |
Pumps | ||||||
Pump Type | Multi–Stage | Multi–Stage | Multi–Stage | Multi–Stage | Multi–Stage | Multi–Stage |
Motor HP | 3 | 3 | 3 | 5 | 5 | 5 |
RPM @ 60 Hz (50 Hz) | 3450 (2900) | 3450 (2900) | 3450 (2900) | 3450 (2900) | 3450 (2900) | 3450 (2900) |
System Electrical | ||||||
Standard Voltage + Amp Draw | 220V, 60Hz, 1PH, 14.5A** | 220V, 60Hz, 1PH, 14.5A** | 220V, 60Hz, 1PH, 14.5A** | 220V, 60Hz, 3PH, 14.2A** | 220V, 60Hz, 3PH, 14.2A** | 220V, 60Hz, 3PH, 14.2A** |
High Voltage Service + Amp Draw | 220V, 50Hz, 1PH, 17.4A** 220V, 50Hz, 3PH, 10.6A** 220V, 60Hz, 3PH, 9A** 460V, 60Hz, 3PH, 5A** |
220V, 50Hz, 1PH, 17.4A** 220V, 50Hz, 3PH, 10.6A** 220V, 60Hz, 3PH, 9A** 460V, 60Hz, 3PH, 5A** |
220V, 50Hz, 1PH, 17.4A** 220V, 50Hz, 3PH, 10.6A** 220V, 60Hz, 3PH, 9A** 460V, 60Hz, 3PH, 5A** |
220V, 50Hz, 3PH, 16.1A** 460V, 60Hz, 3PH, 7A** |
220V, 50Hz, 3PH, 16.1A** 460V, 60Hz, 3PH, 7A** |
220V, 50Hz, 3PH, 16.1A** 460V, 60Hz, 3PH, 7A** |
Systems Dimensions | ||||||
Approximate Dimensions* L x W x H (in / cm) | 27 x 26 x 61 / 69 x 66 x 155 |
27 x 26 x 61 / 69 x 66 x 155 |
30 x 26 x 61 / 75 x 66 x 155 |
32 x 26 x 61 / 80 x 66 x 155 |
32 x 26 x 61 / 80 x 66 x 155 |
37 x 26 x 61 / 94 x 66 x 155 |
Approximate Weight (lbs / kg) | 560 / 250 | 590 / 270 | 620 / 280 | 650 / 300 | 680 / 310 | 700 / 320 |
Test Parameters: 10,000 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 350 psi / 24.13 bar Operating Pressure,
77ªF / 25ªC, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.
* Does not include operating space requirements.
** Varies with motor manufacturer.
Operating Limits
Maximum Feed Temperature (°F / °C) | 85 / 29 | Maximum Free Chlorine (ppm) | 0 |
Minimum Feed Temperature (°F / °C) | 40 / 4 | Maximum TDS (ppm) | 10,000 |
Maximum Ambient Temperature (°F / °C) | 120 / 49 | Maximum Hardness (gpg) | <1 |
Minimum Ambient Temperature (°F / °C) | 40 / 4 | Maximum pH (Continuous) | 11 |
Maximum Feed Pressure (psi / bar) | 85 / 6 | Minimum pH (Continuous) | 2 |
Minimum Feed Pressure (psi / bar) | 45 / 3 | Maximum pH (Cleaning 30 Minutes) | 13 |
Maximum Operating Pressure (psi / bar) | 400 / 28 | Minimum pH (Cleaning 30 Minutes) | 1 |
Maximum Feed Silt Density Index (SDI) | <3 | Maximum Turbidity NTU | <1 |
Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.
System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.
Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.