• 900000GPD PLC Reverse Osmosis Water Filter System Commercial
  • 900000GPD PLC Reverse Osmosis Water Filter System Commercial
  • 900000GPD PLC Reverse Osmosis Water Filter System Commercial
  • 900000GPD PLC Reverse Osmosis Water Filter System Commercial
900000GPD PLC Reverse Osmosis Water Filter System Commercial

900000GPD PLC Reverse Osmosis Water Filter System Commercial

Product Details:

Place of Origin: China
Brand Name: Fenigal/OEM
Certification: CE/NSF etc.
Model Number: ROL-200~900K

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard Export Wood Crate/Carton or Naked wrapped by film
Delivery Time: 15~30 days
Payment Terms: T/T, Western Union, Paypal etc.
Supply Ability: 50 set per month
Get Best Price Contact Now

Detail Information

Technology: Commercial Water Reverse Osmosis Design: Skid Mount
Recovery Rate: 65~75% Feed TDS/ppm: <2,000
Water Temp.: 5~35˚C PH: 4~9
TSS/mg/L: <5 Silt Density Index: <3
Free Chlorine Mg/L: 0 Dissolved Iron Mg/L: <0.1
Warranty: 1 Year Material: SS304/SS316L,carbon Steel
Voltage: 380V,415V,220V,can Be Customized Application: Water Purification,Filtration,pharmceutical,drinking Water,food
Size: Depends,1750*550*1650mm Type: Reverse Osmosis System
Function: Water Purifying, Desalination Desalination Rate: 99%,99.7%
Control: Electronic,Manual/PLC Ro Membrane: Vontron, Hydranautics Or DOW,4040
Pump: CNP / Grundfos,CNP
High Light:

900000GPD Reverse Osmosis Water Filter System

,

PLC 900000GPD Reverse Osmosis Water Filter System

,

900000GPD Reverse Osmosis Water Treatment System

Product Description

900000GPD PLC Reverse Osmosis Water Filter System Commercial

900000GPD Commercial Reverse Osmosis Water Filter System

ROL Series Commercial Reverse Osmosis Systems 200,000~900,000GPD 400V/50Hz or 460V/60Hz

 

Designed to produce low dissolved solids water from tap or well water, these systems use high efficiency reverse osmosis membranes. The product water is used in applications such as semiconductor, boiler

feed, pharmaceutical, municipal, water reuse, food processing, bottling, and a wide variety of other applications.

 

Operation Specifications

Max. feed water temperature: 42°C
Equipment upgrade for TDS up to 5,000 ppm
Hydrogen Sulfide must be removed
Max. Silica tolerance: 25 ppm @ 60% recovery
Feed water TDS: 0-2,000 ppm
Operating pressure: 150 to 250 psi
pH tolerance range: 3-11
Max. Iron content: 0.05 ppm
Feed water pressure: 20 to 80 psi
Hardness over 1 GPG requires water softener
Turbidity should be removed
Operate at higher TDS by lowering recovery

 

Model Number Permeate Flow Rate Pressure Vessel 8" Membranes Motor Rating at 1,000 ppm Approx. Weight Dimensions
GPD M3/D Qty. Qty. 60Hz (hp) 50Hz (kw) LBS KG L”xW”xH” LxWXH (cm)
ROL-4780 200,000 758 4 28 30 22 4700 2136 350x72x80 889x183x203
ROL-5680 225,000 852 5 30 30 22 4850 2205 300x72x80 762x183x203
ROL-6680 270,000 1,023 6 36 40 30 5050 2295 300x72x80 762x183x203
ROL-7680 320,000 1,212 7 42 40 30 5200 2364 300x72x90 762x183x229
ROL-8680 360,000 1,364 8 48 50 37 5750 2614 300x72x90 762x183x229
ROL-9680 410,000 1,553 9 54 60 37 6250 2841 300x72x90 762x183x229
ROL-10680 450,000 1,705 10 60 60 45 7500 3409 300x72x90 762x183x229
ROL-11680 500,000 1,894 11 66 60 45 8500 3864 300x72x80 762x183x203
ROL-11780 550,000 2,083 11 77 75 45 8750 3977 300x72x90 762x213x229
ROL-13780 600,000 2,273 13 91 75 55 9250 4205 350x84x92 889x213x234
ROL-14780 700,000 2,652 14 98 100 75 9650 4386 350x84x94 889x213x239
ROL-16780 800,000 3,030 16 112 2X60 2x37 10200 4636 350x84x96 889x213x244
ROL-18780 900,000 3,409 18 126 2X60 2x37 10650 4841 350x84x98 889x213x249

 

Voltage Codes:

235 = 230v, 3ph, 50hz (up to ROL-9680 only)

236 = 240v, 3ph, 60hz (up to ROL-9680 only)

335 = 380v, 3ph, 50hz (all ROL range)

435 = 400/415v, 3ph, 50hz (all ROL range)

436 = 460v, 3ph, 60hz (all ROL range)

 

Standard Features: Available Options:

8” TFC spiral wound membranes

Stainless steel multi-stage pump with TEFC motor

FRP membrane housings

5 micron cartridge prefilter

PLC based control panel

Programmable time delay and set points

HMI screen

Motor starter

Low pressure switch

High pressure switch

Liquid filled pressure gauges

Permeate conductivity monitor

Permeate & concentrate flow meters

Remote monitoring

Feed water conductivity monitor

Membrane cleaning skid

Product tank level switch

Feed pH monitor with sensor

Feed ORP monitor with sensor

Water and hour meters

Chemical dosing systems

Media prefiltration systems

Ozonation and UV sterilization systems

Water softeners

Skid mounted with pre or post treatment

Containerized RO systems

 

The ideal applications for brackish reverse osmosis systems include:

Metal Finishing
Beverage Production and Bottled Water
Electronics
Pharmaceutical
Mining Industry
Chemical Blending
Safe Drinking Water
Rinse Water
Power Plants
Plating Operations
EDI Pre-treatment
Food and Beverage
Spot Free Product Rinse
Cooling Towers
Laboratory
Boiler Feed Water
Ice Manufacturing
Ion Exchange Pre-treatment

900000GPD PLC Reverse Osmosis Water Filter System Commercial 0

900000GPD PLC Reverse Osmosis Water Filter System Commercial 1


Want to Know more details about this product
I am interested in 900000GPD PLC Reverse Osmosis Water Filter System Commercial could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.